About Armstrong . Contact Us . Events . Search . Site Map . Home

Creating Value for our Worldwide Customers through three generations
Complete Product Line

Commercial Pumps 

Controls 

CBVs, FTVs & Suction Guides 

Domestic and Waste Water 

Design Envelope 

Heat Exchangers 
ABX
PFX
Shell and Tube
Tank Heaters

Residential & Light Commercial Hydronics 

Air & Expansion Control 

HVAC Packages 

Project Services 

Fire Pumps 

Legacy Products 
 Back to the Main Menu



PFX Print this page

 Product Comparison

 Our Recommendations

 Find a Rep

Overview Features Typical Specifications


Typical Specifications

Design

  • The unit shall be provided with an aluminum or stainless steel OSHA splash shield.
  • The units shall be built in accordance with ASME code and when necessary be ASME Code stamped board registered.

Frame

  • The frame plate and pressure plate should be carbon steel SA 516 grade 70.
  • The frame and pressure plate shall be of sufficient thickness to meet the ASME design pressure. Stiffeners or support brackets are not allowed.
  • Carbon steel frame components shall be painted with Armstrong “Harvester Red” epoxy paint.
  • Units with four-inch or greater connections shall be unlined or alloy lined studded ports to mate with raised face or flat faced ANSI flanges. Rubber liners are not allowed.
  • Units with two-inch or smaller connections shall have carbon steel female tapped NPT or male NPT connections if an alloy material is required.
  • Units with two and half or three-inch connections shall be either studded ports or NPT as describe above.
  • The frame design shall allow the thermal plates to be supported by the carry bar, top bar. The guide bar, bottom bar, shall only help properly align the plates.
  • A roller assembly from the carry bar shall support the pressure plate for units taller than 50".
  • Tightening bolts shall be zinc plated carbon steel SA193 B7.

Plates

  • Plates shall be constructed of 316 L Stainless Steel.
  • Plates shall be pressed in a one step stamping process.
  • Plates shall use an integral rolled edge hanging system to provide a rigid hanger device between the plate and carry bar and guide bar. Welded on hanging brackets or stiffeners are not acceptable.
  • Plates shall be permanently marked to indicate plate material and thickness.

Gaskets

  • The gaskets shall be a one-piece construction with a double gasket barrier at the port region. The area isolated by the double gasket shall be vented to the atmosphere, so that a gasket failure is detected by leakage to the exterior prior to any possible cross contamination.
  • Gaskets are to be “mechanically fixed”. Glued gaskets are not acceptable.
  • The gaskets are to be made of NBR.

Selection, Certification and Testing

  • The manufacturer shall hydro-test the unit to 1.3 times the design pressure as directed by ASME Code.

  • PFX Specification in Word format

  • PFX - ARI 400 Specification in Word format

  • Additional Links
    PDF Brochures

    Installation and Operation Guides

    Images & Drawings



    Copyright © 2010 S.A. Armstrong Limited | Terms & Conditions of Use | Privacy